Guide to Digital Image Artifacts and Corrections in Medical Imaging Study Guide
This guide provides a comprehensive overview of digital image artifacts encountered in medical imaging. It covers the fundamental principles behind aliasing and Moire patterns, flat-panel detector defects such as dead pixels, and temporal issues like image lag (ghosting). For each artifact, the guide explains its origin, how it manifests visually, and the technical strategies employed for its correction or reduction. Techniques discussed include gain calibration (flat-fielding) and interpolation
Save this study guide to your study set
Your learning path
Glossary of Common Radiographic Terms
Glossary of Common Radiographic Terms
A glossary defining essential terminology for radiographic equipment, imaging modalities, and radiation exposure parameters.
- Radiographic equipment components
- Imaging modalities
- Radiation exposure parameters
- Radiation safety and measurement
X-Ray Imaging System Components
X-Ray Imaging System Components
An overview of the essential hardware and components required for x-ray production and diagnostic imaging.
- High voltage generator
- Operating console
- X-ray tube
- Tube housing
- Collimator
- Light field
- Radiographic table
X-ray Equipment Components and Control Panel Operation
Diagnostic X-ray Equipment and Control Components
An overview of diagnostic X-ray system components, digital image receptors, and operating console technical settings.
- Generator
- X-ray tube
- Collimator
- Digital image receptor
- Table Bucky
- Operating console
- kVp (kilovolts peak)
- mA (milliamps)
- mAs (milliamp-second)
- Exposure switch
Chronological Timeline of Radiology Services
Medical X-ray Machine and Radiology
A medical X-ray machine with a patient table in a clinical diagnostic room illustrates healthcare technology and radiology services.
- medical X-ray machine
- patient table
- clinical diagnostic room
- healthcare technology
- radiology services
Mastering Basic Medical Imaging Equipment
Proper use of imaging equipment requires mastering technique settings, tube locks, source-to-image-distance, and alignment of the tube, image receptor, and body part.
- kV and mAs settings
- Source-to-image-distance
- Tube and IR alignment
- Upright bucky positioning
- Table bucky alignment
- Transverse and longitudinal movement
- Lock stops (detents)
- Image receptor orientation
External and Internal X-Ray Tube Components
External and Internal X-Ray Tube Components
This topic covers the support systems, protective housing, and envelope structures of the X-ray tube.
- Ceiling support system
- Floor-to-ceiling support system
- C-Arm Support System
- Protective Housing
- Leakage radiation
- Envelope
- Window
The Cathode and Thermionic Emission
The X-ray Tube Cathode
The cathode is the negative side of the x-ray tube that produces a thermionic cloud and focuses the electron stream to the anode.
- Cathode
- Filament
- Thermionic emission
- Thermionic cloud
- Dual focus
- Space charge effect
- Saturation current
- Focusing cup
- Cathode wear
The Anode, Rotor, and Stator
X-ray Tube Anode Components and Function
The anode is the positive side of the x-ray tube containing the target surface where x-rays are produced.
- Stationary Anode
- Rotating Anode
- Focal Track
- Tungsten
- Rhenium
- Molybdenum
- Graphite
- Heat Load Capacity
- Focal Spot Blooming
Mechanics of the Rotating Anode
The stator and rotor form an electromagnetic induction motor used to spin the anode.
- Electromagnetic induction motor
- Stator and rotor interaction
- Molybdenum anode shaft
- High speed rotation problems
- Coast time
The Line Focus Principle and Focal Spots
The Line Focus Principle
The Line Focus Principle determines the best anode angle to achieve required field coverage while maintaining optimal spatial resolution and heat load capability.
- Actual focal spot
- Effective focal spot
- Anode angle
- Spatial resolution
- Heat load capability
- Field coverage
Understanding the Anode Heel Effect
Understanding the Anode Heel Effect
The anode heel effect causes radiation intensity to be greater on the cathode side of the tube due to the line focus principle.
- Anode heel effect
- Line focus principle
- Radiation intensity
- Effective focal spot size
- Focal spot blur
- Source to image distance
- Field size
Anode and X-ray Tube Preservation
Anode and X-ray Tube Preservation
This module covers anode and tube preservation, including heat dissipation, tube rating charts, and anode cooling calculations.
- Anode heat capacity
- Heat dissipation mechanisms
- Tube rating charts
- Anode cooling charts
- Heat units (HU)
- Dielectric oil
- Filament vaporization
- Rotor prep
Filament Processes and Thermionic Emission
Thermionic Emission and Filament Dynamics
The relationship between milliamperage, filament temperature, and the production of a thermionic cloud through thermionic emission.
- milliamperage (mA)
- thermionic emission
- thermionic cloud
- space charge
- mAs (milliamps-second)
- filament temperature
Overview of the CR Process
Computed Radiography Process and Components
An overview of the computed radiography process including the cassette, photostimulable imaging plate, and image reader.
- Computed radiography process
- Photostimulable phosphor imaging plate
- Image reader
- Video display monitors
- Workstations
- Barium fluorohalide with europium
- Latent image
- Wide dynamic range
- Exposure latitude
The Computed Radiography Imaging Process
Computed Radiography Imaging Process
The computed radiography imaging process involves exposing, stimulating, reading, and erasing a photostimulable phosphor plate.
- CR Reader
- Photostimulable phosphor (PSP)
- Latent image
- Red laser beam
- Translation
- Photomultiplier tube (PMT)
- Optical filter
- Analog-to-digital converter (ADC)
- Digital-to-analog converter (DAC)
- Erase cycle
Understanding Computed Radiography (CR) Imaging
Read · 6 min
- Import & open
Flashcards
Import to get started
- Import & open
Quiz
Import to get started
- Import & open
Practice test
Import to get started
- Import & open
Listen
Import to get started
- Import & open
Tutor Me
Import to get started
- Import & open
Watch
Import to get started
- Import & open
Chat
Import to get started
- Import & open
Arcade
Import to get started
CCD and CMOS Indirect Capture Imaging
CCD and CMOS Indirect Capture Imaging
CCD and CMOS are used to convert light into an electrical signal for indirect capture imaging systems.
- Charge-coupled device (CCD)
- Complementary metal oxide semiconductor (CMOS)
- Indirect flat panel detection
- Scintillator
- Fiber optics
- Photosensitive receptor
- Silicon chip
- Digital radiography
- Digital mammography
- Digital fluoroscopy
- TFT comparison
- Light detection
- Resolution
- Power use
Quality Assurance and Quality Control Fundamentals
Introduction to Quality Assurance and Control
Quality assurance and quality control activities monitor radiology equipment performance and diagnostic imaging department procedures to ensure optimum diagnostic quality and minimum radiation exposure.
- Quality assurance
- Quality control
- Administrative procedures
- Visual inspection
- Environmental inspection
- Performance testing
- Radiation output reproducibility
- Generator load factors accuracy
- Radiation output linearity
- X-ray beam filtration
Radiation Detection and Area Monitoring
Radiation Detection and Measurement Instruments
Instruments designed to detect radiation operate in pulse or rate mode, while instruments designed to measure radiation intensity operate in integrate mode using gas-filled ionization chambers.
- Radiation detection and measurement
- Pulse mode
- Rate mode
- Integrate mode
- Gas-filled detectors
- Ionization chamber
- Radiation intensity
- Area monitoring
- Fluoroscopic scatter radiation exposure rates
- Dose area product (DAP) meter
- X-ray output
- Beam quality
Radiation Dose Limits and Imaging Artifacts
Digital Image Artifacts and Corrections
This document discusses aliasing, flat-panel artifacts, and image lag including methods for compensation and reduction.
- Aliasing
- Moire pattern
- Flat-panel artifacts
- Dead pixels
- Gain calibration
- Flat-fielding
- Interpolation
- Image lag
- Ghosting
Understanding and Correcting Digital Image Artifacts in Medical Imaging
Read · 4 min
- Import & open
Flashcards
Import to get started
- Import & open
Quiz
Import to get started
- Import & open
Practice test
Import to get started
- Import & open
Listen
Import to get started
- Import & open
Tutor Me
Import to get started
- Import & open
Watch
Import to get started
- Import & open
Chat
Import to get started
- Import & open
Arcade
Import to get started
Make it your own.
Keep these readings and topics in a new study set, or add them to one you already use.