Oxygen therapy is a critical intervention used whenever a patient's subjective and objective condition warrants it. While it is a life-saving treatment, clinicians must remember that "anoxia not only stops the machine, it wrecks the machinery". When administering oxygen, Respiratory Therapists (RTs) must select the appropriate device, assemble it correctly, and continuously monitor the patient's , cardiac status, and ventilatory status.
One of the most important distinctions in respiratory care is the difference between low-flow and high-flow systems. It is vital to note that "low flow" does not necessarily mean "low ".
Low-Flow Oxygen Delivery Systems
Low-flow systems deliver an ranging from 0.22 to 0.80. In these systems, the RT sets a specific flow rate, but this rate is lower than the patient's actual inspiratory flow demand. Because the device cannot meet the patient's full demand, the patient draws in additional room air to supplement the oxygen. Consequently, the actual delivered is variable and is affected by the patient's breathing pattern, including tidal volume (), respiratory rate (RR), and inspiratory flow rate.
Nasal Cannula
The nasal cannula is a common low-flow device used to deliver oxygen through the nares.
- Flow Rate: Typically 1–6 L/min in adults.
- Range: Approximately 0.24 to 0.44.
- Advantages: It is very comfortable, allowing patients to eat, talk, and perform hygiene without removal.
- Disadvantages: It can cause significant nasopharyngeal mucosal irritation (drying) and skin irritation at pressure points like the ears.
Exam Tip: Estimating with a Nasal Cannula Assuming a normal RR and , each 1 L/min of oxygen increases the by approximately 4%.
Formula:
Example: For a flow of 4 L/min: